[Q22-Q45] Use the best ways of preparing for NS0-173 Exam Dumps with Free4Torrent Network Appliance NS0-173 PDF Dumps [2021]

Share

Use the best ways of preparing for NS0-173 Exam Dumps with Free4Torrent Network Appliance NS0-173 dump PDF [2021]

Network Appliance NS0-173 exam candidates will surely pass the Exam if they consider the NS0-173 dumps learning material presented by Free4Torrent.

NEW QUESTION 22
Click the Exhibit button.

A customer wants to ensure that FlexPod Datacenter connections to the storage layer are highly available. Which two configurations shown in the exhibit satisfy the customer's requirements? (Choose two.)

  • A. III.
  • B. IV
  • C. I.
  • D. II.

Answer: A,B

 

NEW QUESTION 23
You are configuring high availability within the network layer of your FlexPod configuration.
In this scenario, what are two Cisco best practices for designing vPC on your Cisco 9000 Series switches?
(Choose two.)

  • A. Port channels should be configured for LACP passive mode.
  • B. Peer keep-alive connectivity between the switches should be established.
  • C. A minimum of four 10GB Ethernet connections are required for vPC.
  • D. The vPC auto-recovery feature should be enabled.

Answer: B,C

Explanation:
vPC also relies on the periodic keepalive messages to determine when one of the connected devices on the peer link fails.
vPC peer link - The link used to synchronize states between the vPC peer devices. Both ends must be on 10- Gigabit Ethernet or 40-Gigabit Ethernet interfaces.
Reference:
configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide/ b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide_chapter_0111.html

 

NEW QUESTION 24
A client has a FlexPod Datacenter solution with four active fabric links in port channel mode established between the Cisco Fabric Interconnects and the IOMs on a Cisco 5108 blade chassis. The blade chassis is fully populated with Cisco UCS B200M5 blades. A worker in the data center inadvertently unplugs the fourth uplink cable from IOM-A while working in the rack.
In this scenario, what happens to the network traffic?

  • A. Connectivity for servers 3, 4, 7, and 8 all fail over to IOM-B.
  • B. Traffic is load-balanced within IOM-A.
  • C. There is a loss of connectivity for servers 4 and 8.
  • D. Traffic is load-balanced within IOM-B.

Answer: A

 

NEW QUESTION 25
A customer is planning to deploy a FlexPod solution for a large scale SAN requirement that uses the FC protocol. The customer plans to use Smart Zoning in the configurations to reduce the number of TCAM entries in the zoning process.
In this scenario, which design would enable the customer to use Smart Zoning?

  • A. storage connected to Cisco Nexus 9000 Series switches
  • B. storage directly connected to Cisco UCS Fabric Interconnects
  • C. storage connected to Cisco MDS switches
  • D. storage connected to Cisco Nexus 5000 Series switches

Answer: C

 

NEW QUESTION 26
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)

  • A. a DS4246 with twenty-four 6 TB NL-SAS HDDs
  • B. a two-node FAS8200 with a 4 TB NL-SAS HDD
  • C. a DS224C with twenty-four 3.8 TB SSDs
  • D. a two-node AFF A200 with a 3.8 TB NSE SSD

Answer: B,C

 

NEW QUESTION 27
You are asked to design a FlexPod solution that meets the minimum requirements and includes Application Centric Infrastructure (ACI).
Which three Cisco components are required in this scenario? (Choose three.)

  • A. Cisco Nexus 3000 Series switches
  • B. Cisco Nexus 9000 Series switches
  • C. Cisco Nexus 2000 Series Fabric Extender
  • D. Cisco UCS Series Fabric Interconnects
  • E. Cisco UCS B-Series servers

Answer: B,D,E

 

NEW QUESTION 28
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)

  • A. DualWire Management mode
  • B. Cluster mode
  • C. Direct Connect mode
  • D. SingleConnect mode
  • E. Multipath mode

Answer: A,C,D

Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack- Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C- Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series- Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

 

NEW QUESTION 29
You are designing a FlexPod solution that requires 32 ports running at 40 Gbps.
To satisfy this requirement, which Cisco Fabric Interconnect should you deploy?

  • A. 6296UP
  • B. 0
  • C. 6332-16UP
  • D. 6248UP

Answer: B

Explanation:
FI 6332 is a one-rack-unit (1RU) 40 Gigabit Ethernet, and FCoE switch offering up to 2.56 Tbps throughput and up to 32 ports. The switch has 32 40Gbps fixed Ethernet.

 

NEW QUESTION 30
A customer has several existing standalone Cisco UCS C-Series servers that they would like to repurpose and add to their FlexPod Datacenter solution.
Which action should the customer perform on these servers before using UCS Manager?

  • A. Zero-out the FlexFlash cards on each server.
  • B. Reboot the CIMC on each server.
  • C. Remove the hard disks on each server.
  • D. Reset the CIMC to the factory settings on each server.

Answer: D

Explanation:
On rare occasions, such as an issue with the current running firmware, troubleshooting a server may require you to reset the CIMC to the factory default. When this happens, all user-configurable settings are reset. This procedure is not part of the normal server maintenance. After you reset the CIMC, you are logged off and must log in again. You may also lose connectivity and may need to reconfigure the network settings.

 

NEW QUESTION 31
Which two Unified Computing System capabilities are required to achieve stateless computing? (Choose two.)

  • A. service profiles
  • B. blade servers
  • C. boot from SAN
  • D. templates

Answer: A,B

Explanation:
Cisco introduced the idea of stateless computing with its blade server design.
A Cisco UCS instance allows you to quickly align computing resources in the data center with rapidly changing business requirements. This built-in flexibility is determined by whether you choose to fully implement the stateless computing feature.
Pools of servers and other system resources can be applied as necessary to respond to workload fluctuations, support new applications, scale existing software and business services, and accommodate both scheduled and unscheduled downtime. Server identity can be abstracted into a mobile service profile that can be moved from server to server with minimal downtime and no need for additional network configuration.

 

NEW QUESTION 32
You are configuring Cisco UCS servers for FC SAN boot and want to perform zoning on your Cisco Nexus 5000 series switches.
In this scenario, which statement is correct?

  • A. SAN links are required between the Cisco Fabric Interconnects and the Nexus 5000 switches.
  • B. FC zoning on the Nexus series switches is not supported; zoning can be done only on the Cisco Fabric Interconnects.
  • C. An iSCSI license on the NetApp storage controller is required.
  • D. The corresponding FC ports on your NetApp storage array must be configured in LACP mode.

Answer: B

 

NEW QUESTION 33
Click the Exhibit button.

You are designing a FlexPod Datacenter solution for Microsoft Windows 2012 with Hyper-V. All hosts will boot from the SAN, including management hosts. The management hosts are Cisco C-Series servers.
Referring to the exhibit, which adapters are required to boot the management servers from the SAN?

  • A. two 1GbE NICs
  • B. two 10GbE NICs
  • C. two 10GbE CNAs
  • D. two 8Gb HBAs

Answer: B

 

NEW QUESTION 34
Two data centers are 75km apart. The customer wants to deploy a FlexPod solution in each data center to maintain high availability between the two sites with minimal possible data loss.
In this scenario, which technology would you use at the NetApp storage layer?

  • A. SnapVault
  • B. SnapMirror
  • C. FlexArray
  • D. MetroCluster

Answer: D

 

NEW QUESTION 35
A customer is planning to use a pair of MDS switches in a FlexPod design to host a few SAN workloads.
In this scenario, which two features should be enabled on the MDS switches for a successful configuration? (Choose two.)

  • A. NPIV
  • B. port-channel-trunk
  • C. NPV
  • D. fport-channel-trunk

Answer: A,B

 

NEW QUESTION 36
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)

  • A. Cisco
  • B. NetApp
  • C. Red Hat
  • D. VMware
  • E. Microsoft

Answer: A,B,C

 

NEW QUESTION 37
Click the Exhibit button.

Referring to the exhibit, what is the name given to the link between the two Cisco Nexus switches?

  • A. vPC peer link
  • B. vPC peer domain
  • C. vPC Domain ID
  • D. vPC peer connection

Answer: A

 

NEW QUESTION 38
A customer wants to deploy a performance-sensitive workload while leveraging NetApp Snapshot technology and technologies such as NAS and SAN.
Which architecture satisfies these requirements?

  • A. NetApp AFF
  • B. NetApp SolidFire
  • C. NetApp EF-Series
  • D. NetApp StorageGRID

Answer: B

 

NEW QUESTION 39
A customer with a FlexPod Express solution wants to enable remote access to the NetApp storage component.
In this scenario, which two access methods are recommended? (Choose two.)

  • A. Telnet
  • B. RDP
  • C. SSH
  • D. SAML

Answer: A,C

 

NEW QUESTION 40
You want to deploy a FlexPod Datacenter solution based on the minimum hardware requirements.
Which three components must be deployed in highly available pairs to accomplish this task? (Choose three.)

  • A. Cisco UCS Fabric Interconnects
  • B. NetApp FAS Storage Controllers
  • C. Cisco USC Nexus Switches
  • D. Cisco APICs
  • E. Cisco UCS 5108 Chassis

Answer: A,B,E

 

NEW QUESTION 41
You are designing a FlexPod solution with a 2-node storage system, multiple compute chassis, and ACI.
In this scenario, which two network switches are required? (Choose two.)

  • A. core switch
  • B. spine switch
  • C. leaf switch
  • D. cluster interconnect switch

Answer: B,C

 

NEW QUESTION 42
Your customer has a FlexPod solution with a 2-node switchless ONTAP system, Cisco Nexus 93108 switches, and Cisco UCS B-Series servers. The customer wants to expand to a 4-node ONTAP storage cluster.
Which configuration is valid for expansion?

  • A. Add one Nexus 3232C switch for the cluster interconnect.
  • B. Add two Nexus 3232C switches for the cluster interconnect.
  • C. Use the existing Nexus 93108 switches for the cluster interconnect.
  • D. Add two Nexus 93108 switches for the cluster interconnect.

Answer: B

 

NEW QUESTION 43
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?

  • A. MDS9148>show fcfwd
  • B. MDS9148>show flogi database
  • C. MDS9148>show fcdomain
  • D. MDS9148>show fcc

Answer: B

 

NEW QUESTION 44
An architect is designing a FlexPod environment with Cisco Nexus 5000 switches to SAN boot all of the ESXi hosts over FC.
In this scenario, what should the LUN ID number be?

  • A. LUN 3
  • B. LUN 1
    Section: (none)
    Explanation
  • C. LUN 2
  • D. LUN 0

Answer: D

 

NEW QUESTION 45
......

Accurate & Verified Answers As Seen in the Real Exam here: https://www.free4torrent.com/NS0-173-braindumps-torrent.html