[Q90-Q107] Best Quality Network Appliance NS0-194 Exam Questions Free4Torrent Realistic Practice Exams [2021]

Share

Best Quality Network Appliance NS0-194 Exam Questions Free4Torrent Realistic Practice Exams [2021]

Critical Information To NetApp Certified Support Engineer Pass the First Time

NEW QUESTION 90
Which statement is true about a switchless cluster?

  • A. A switchless cluster can support up to one node per cluster port.
  • B. Converting a switchless cluster to a switched cluster is disruptive.
  • C. A switchless cluster can only be used for a system with two controllers in one chassis configuration.
  • D. In a switchless cluster, the network options switchless-cluster -enabled parameter must be set to true.

Answer: D

 

NEW QUESTION 91
You receive the error shown below on a FAS2750 HA pair.
Mon Jun 24 00:27:30 UTC [NetappA: scsi_cmdblk_strthr_admin:
scsi.cmd.checkCondition:error]: Unknown device 0a.00.99: Check Condition: CDB
0x12: Sense Data SCSI:hardware error - (0x4 - 0x44 0x0 0x0) (0).
The system is cabled as shown in the exhibit.

What should you do to clear the error?

  • A. Replace the controller of controller A.
  • B. Replace the cable connected to controller A's 0a port.
  • C. Re-cable the system per the FAS2750 installation guide.
  • D. Replace the controller of controller B.

Answer: A

 

NEW QUESTION 92
Which database must be installed for deployments of OnCommand Unified Manager 6.x and OnCommand Performance Manager for Linux installations?

  • A. Oracle
  • B. MySQL
  • C. MS SQL Server
  • D. Sybase

Answer: B

 

NEW QUESTION 93
You are trying to determine why AutoSupport notifications are not being sent.
Which two types of output would be used first to solve this problem? (Choose two.)

  • A. output of the autosupport history show command
  • B. the MGWD.log
  • C. the notifyd.log
  • D. output of the network interface show command

Answer: A,C

 

NEW QUESTION 94
Exhibit:

A customer receives the AutoSupport message shown below.
''(?] Sat Aug 23 13:00:27 PDT [hostname: env_rngr: callhome.c.fan.fru.fault:error] :
Call home for CHASSIS FAN FRU FAILED: SysFan3 F2 (?] Sat Aug 23 13:00:32
PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis fan Sysfan3 F2 is ok"
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?

  • A. Update the Service Processor firmware.
  • B. Update Data ONTAP to 8.1.4 at the latest patch level.
  • C. Disconnect the controller from the mains, wait two minutes, and re-connect it in the next maintenance window.
  • D. Replace the fan.

Answer: B

 

NEW QUESTION 95
Exhibit:

A customer receives the AutoSupport message shown below.
''(?] Sat Aug 23 13:00:27 PDT [hostname: env_rngr: callhome.c.fan.fru.fault:error] :
Call home for CHASSIS FAN FRU FAILED: SysFan3 F2 (?] Sat Aug 23 13:00:32
PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis fan Sysfan3 F2 is ok"
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?

  • A. Update the Service Processor firmware.
  • B. Update Data ONTAP to 8.1.4 at the latest patch level.
  • C. Disconnect the controller from the mains, wait two minutes, and re-connect it in the next maintenance window.
  • D. Replace the fan.

Answer: B

 

NEW QUESTION 96
Referring to the exhibit.

A storage administrator tells you that a company security mandate was applied to remove all CIFS share level permissions of everyone - full control. Now users are unable to access CIFS shares.
The storage virtual machine (SVM) is named "SVM1" on clustered Data ONTAP 8.3.1. The storage administrator wants to know what can be done to restore full control access to users that are receiving "access denied" errors.
The storage administrator has provided you with the vserver cifs share show command output of one of the CIFS shares with issues as shown in the exhibit.
Which two steps must you perform to solve the problem? (Choose two.)

  • A. Execute the ::> vserver cifs share access-control delete -vserver SVM1 -share test9 - user-or-group domainA \lnterngroup command from the controller.
  • B. Ensure that, in Active Directory, the desired users are members of the domainA \temps group.
  • C. Ensure that, in Active Directory, the desired users are members of the domainA\companyusers group.
  • D. Execute the ::> vserver cifs share access-control delete -vserver SVM1 -share test9 - user-or-group Everyone command from the controller.

Answer: A,C

 

NEW QUESTION 97
Exhibit:



You are provided output from the sysconfig -a and sysconfig -r commands of a MetroCluster cluster for disk switch 1:15.45 SN#J9YG1U3L, as shown In the exhibit.
Which two statements are true in this scenario? (Choose two.)

  • A. The disk is located at the file3 site.
  • B. The disk is located at the file2 site.
  • C. The disk is in shelf 2 bay 13.
  • D. The disk is located in switch3.

Answer: A,C

 

NEW QUESTION 98
Which NetApp HCI component communicates with activeiq.solidfire.com and the Cloud Data Services portal?

  • A. the NetApp Trident software
  • B. the management node (mNode)
  • C. the NetApp Element software vSphere plug-in
  • D. the NetApp Element software Management Interface

Answer: B

 

NEW QUESTION 99
Exhibit:

You are attempting a storage giveback, but the process does not finish successfully. Referring to the exhibit.
What is the problem?

  • A. There are active CIFS or NFSv4 connections.
  • B. The giveback failed on the node root aggregate.
  • C. There are active cluster -02 was not ready for giveback.
  • D. An aggregate has failed.

Answer: A

 

NEW QUESTION 100
A customer has one storage virtual machine (SVM) that is using Fibre Channel as a protocol (FCP). Some clients are successfully accessing LUNs on this SVM.
The zoning is done by using worldwide port names (WWPNs). The customer creates a second SVM for Fibre Channel and wants to access new LUNs in this SVM from the same clients.
Which three statements are true in this scenario? (Choose three.)

  • A. Fibre Channel zoning does not need to be changed if the second SVM uses the same ports as the first SVM.
  • B. The initiator groups (igroups) from the first SVM are also working for the second SVM.
  • C. You must map the new LUNs in the second SVM to the correct initiator group (igroup).
  • D. FCP must be enabled on the second SVM.
  • E. Fibre Channel zoning must be reconfigured for the new SVM.

Answer: A,B,D

 

NEW QUESTION 101
Click the Exhibit button at the right.
A customer reports that a node panicked due to a multidisk failure.
While in take over, the customer reviewed the output of the sysconfig -a command and noticed a discrepancy in the shelf stack as shown in the exhibit.

The customer proceeded to examine the power supplies in the stack of shelves; all were functional.
Which step would you take to solve this problem?

  • A. Replace the motherboard in the broken node.
  • B. Reseat all the disks in shelf 1.
  • C. Replace the SAS cable from adapter 2d to shelf 1.
  • D. Replace the shelf chassis of shelf 1.

Answer: D

 

NEW QUESTION 102
A customer observes write latencies above 40 ms on a clustered Data ONTAP system with two FAS3220s for a period of several minutes each night.
During performance analysis, you discover that several back-to-back CPs occur In this scenario, which two configuration changes will reduce the write latencies? (Choose two.)

  • A. Migrate the LIF with the highest network receive rate to a faster port.
  • B. Add flash cache cards to the nodes.
  • C. Move the volume with the highest write load to an aggregate with faster disks.
  • D. Add more disks to the aggregate.

Answer: B,C

 

NEW QUESTION 103
A customer wants to upgrade a cluster to a new version of ONTAP. In this scenario, what are two ways to ensure a successful upgrade? (Choose two.)

  • A. Use the Upgrade Advisor report.
  • B. Use Config Advisor.
  • C. Use OnCommand System Manager.
  • D. Use OnCommand Unified Manager.

Answer: A,C

 

NEW QUESTION 104
A customer discovers fault lights on both HA interconnect links in a 2-node cluster. The customer is concerned about the cluster's ability to serve data.
Which statement is true in this scenario?

  • A. The HA interconnect links would automatically recover from this temporary state.
  • B. ONTAP clustering does not depend on HA interconnect links and will continue to serve data.
  • C. You should perform a takeover and serve the data in failover state.
  • D. You should reboot both nodes.

Answer: B

 

NEW QUESTION 105
A customer has replaced both interconnect cables on a FAS3240 HA pair with IOXM because they were damaged. After replacing the cables, the customer receives the error shown below.
"HA interconnect port 1 of this appliance seems to be connected to port 2 on the partner appliance." In this scenario what is the cause of this error?

  • A. The interconnects are cross-cabled, you must connect c0a with c0a and c0b with c0b.
  • B. The interconnect cables must not be replaced while the controllers are up and running.
  • C. c0a and c0b are 10Gbit Ethernet ports which must not be used for the interconnect.
  • D. You must issue the if config down . . . command followed by the if config up ... command for both ports, on both controllers, after replacing the cables.

Answer: A

 

NEW QUESTION 106
Referring to the exhibit.

A database administrator explains that the backup job scheduled to complete by 7:00 AM is not completing as fast as expected. You log in to theFAS3240 system and execute a few commands and obtain the output shown in the exhibit.
Which system resource would you eliminate as a eliminate as a problem based on the command output?

  • A. network
  • B. disk
  • C. CPU
  • D. memory

Answer: D

 

NEW QUESTION 107
......

NS0-194 EXAM DUMPS WITH GUARANTEED SUCCESS: https://www.free4torrent.com/NS0-194-braindumps-torrent.html